LCU is a dual redundant shared input and output control device designed specifically for rail vehicle applications. Based on the contactless control and drive technology of signal acquisition and self-diagnosis technology, it completely replaces the traditional relays in the vehicle electrical control system, directly controls and drives the train control signals and electrical equipment, fundamentally solves the shortcomings of the traditional electric contact logic control circuit, improves the safety and reliability of vehicle control, improves the economy and convenience of operation, and meets the needs of the train control circuit under the influence of complex environments for improved safety performance.
Support 6 channels with DC 0~10V voltage type/4~20mA current type analog input
Support 2 channels of 0~10V voltage analog output
Support 2-way 4~20mA current analog output
Support 4-way external power supply
Digital input and output (Mutually redundant AB group)
Supports up to 75 digital input detections, high level is DC 16.8~30V, low level is DC 0~7V; each input has a diagnostic function, and the maximum input current is no more than 5mA
Supports up to 50 digital outputs, with high level of DC 16.8~30V and low level of DC 0~7V; each output channel has overload protection function, with maximum current of 8A, 100ms, and 2A rated operation; each output adopts dual switch control, with output feedback and diagnosis function
Provides 5 dry contact outputs, output channels have overload protection function, maximum current 8A, 100ms, 2A rated operation
coding
Encoding settings
Support DIP switch encoding setting
External Interface
Network Interface
Support 2-way 10/100M adaptive Ethernet
MVB Interface
Supports 2 redundant MVB bus interfaces
Serial Port
Support 1 RS485 and 1 RS232
CAN Interface
Support 4 CAN channels, front panel CAN1 and CAN2 are redundant, bottom panel CAN3 and CAN4 are redundant
Power Supply
Input voltage
DC 110V/DC 24V
Power consumption
≤ 100W
Power protection
Input overvoltage and input overcurrent protection
Environmental Indicators
Operating temperature
-20℃ ~ +70℃
Storage temperature
-40℃ ~ +85℃
Protection level
IP20
Relative humidity
The maximum relative humidity is not more than 95%